• Ahri 210/240 Air Conditioner Test Laboratory
  • Ahri 210/240 Air Conditioner Test Laboratory
  • Ahri 210/240 Air Conditioner Test Laboratory
  • Ahri 210/240 Air Conditioner Test Laboratory
  • Ahri 210/240 Air Conditioner Test Laboratory
  • Ahri 210/240 Air Conditioner Test Laboratory

Ahri 210/240 Air Conditioner Test Laboratory

Type: Performance Test Machine
Certification: UL, CE, CCC
Condition: New
Transport Package: Wooden Case
Trademark: GZ-LANS
Origin: China
Customization:
Gold Member Since 2010

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
LS-PSC14
HS Code
9031809090
Production Capacity
100 Set/ Year

Product Description

AHRI210/240 Air Conditioner Test laboratory
1.Synopsis of the Equipment
This equipment is for measuring the calories of Air-con. It also measures various kinds of data including pressure and electric properties of the Air-con. And it consists of indoor laboratory (1 room), outdoor laboratory (1 room), air handling unit, refrigerating machine, airflow meter, power panel, computer system and so on.

2.Definition of the Test Unit
Type
Window type Air-con. 
Split type Air-con. 
Cassette type Air-con. 
Floor standing type Air-con. 
Fan coil unit
Capacity
Cooling capacity 9, 000BTU/h ~60, 000BTU/h (2, 250kcal/h~15, 000kcal/h). 
Heating capacity 9, 000BTU/h ~60, 000BTU/h (2, 250kcal/h~15, 000kcal/h). Amount of dehumidify max. 
15 L/h (indoor)
Water flow 0~4m3/h
Air flower rate (Indoor) 5~60m3/min(175~2, 100CFM)
Power 1 60~300V 40A continuous rating (at 230V). 
3 60~600V 30A continuous rating (at 380V). 
Size Indoor unit no bigger than W×D×H=1200×800×1900MM
Outdoor unit no bigger than W×D×H=1200×800×1200MM
Window unit no bigger than W×D×H=800×800×800MM

3.Inspection Conditions
Repeatability Test (by heater)
Test method ------will test 2 times at 3 grade. 
Acceptable heater difference ----- 1.5% beneath. 
Standard sample as compared with to test (by ETL unit). 
Test method ------will test 3 times at 3 grade of ETL sample. 
Acceptable heater difference ------±1.5% compared to ETL Test result. 
For fan coil unit the balance between water side and air side ------5% beneath
Conditions other than these will match the temperatures established in the correlative standards and rules


Ahri 210/240 Air Conditioner Test Laboratory