Product Description
The Heat Pump Water Heater Performance Test Room includes the
Household Heat Pump Water Heater Performance Test Room and the
Commercial Heat Pump Water Heater Performance Test Room.
The test room can be used to determine the Heating Capacity, the
Heating Power Consumption, the COP, the Defrost Performance, the Low
Temperature Performance, the Hot Water Storage Performance, the Heat
Insulation, and the Water Pressure Loss of the Heat Pump Water Heater.
The Test Objects could be the Air to Water Heat Pump Water Heater, the
Water to Water Heat Pump Water Heater, the Tank Storage Heat Pump
Water Heater, the Recycled Water Heat Pump Water Heater, the Split
Type Heat Pump Water Heater, and the Auxiliary Electric Heater Heat
Pump Water Heater etc.
Test Standards
• BS/EN 16147 Heat pumps with electrically driven compressors --
Testing and requirements for marking of domestic hot water
units
• AS/NZS 5125 Heat Pump Water Heaters -- Performance
assessment
• ASHRAE 137 Methods Testing Efficiency of Space --
Conditioning/Water Heating Appliances that Include a
Desuperheater Water Heater